When several RAVENNA devices are present on the same network, one is elected as PTP Master, and the other ones as PTP Slave.
Only the PTP Master is able to lock to an external reference (i.e. Wordclock, Video reference,...).
If the PTP Master device fails, one of the Slave device will be elected to Master, but by default will be on its internal clock.
The PTP priority priorities has to be configured on the Slave devicedevices, to have it set on the external clock in the case it becomes Master.

Setup example :

- Horus 1 master with sync on WordClockVideo Ref.
- Horus 2 slave, but needs to fallback as master with sync on WordClockon Video Ref.

Info
iconfalse
titlePrerequisite
Your Merging RAVENNA device must be running firmware XXXX 3.9.0b34718 or above.

 

  1. On each Horus, select WCK Video in the I/O & Sync Page.
    On the Master PTP, the Horus will be synchronized on Video, the PTP slave will show Video sync red :

    Image Added

  2. Open the advanced pages of the slave device, and go in the PTP tab.

  3. Tick the "Manual" box and set "Priority 1" to 120 130 (Default value 127).
    The other PTP Parameters should not be modified.



When previous master comes back

Tip
titlePTP Priority values

High values have low priority, and low values have high priority; 1 is the highest priority and 255 the lowest.
By default, all Merging devices are set with a priority value of 127, and an internal algorithm is used to determine which device is elected as master when several devices have the same PTP priority value.