- Please check the IP adresses, your ASIO network card and the RAVENNA device must be in the same range.
If Horus / Hapi are configured to use their default IP addresses, it will be 169.254.xxx.xxx, then your Native network adapter have to be in the same range 169.254.xxx.xxx If the default IP adress is used in the Horus/Hapi, your network card have to be set to use an automatic IP address. - If you have several network adapters, make sure that the other networtks are NOT in the same IP range, Windows is not able to handle 2 networks with the same range.
If the RAVENNA network is using the 169.254.xxx.xxx range, your other network(s) should for example be set to 192.168.xxx.xxx - Make sure the ASIO Clock setting in Horus/Hapi Setup > System is set to Auto or On.
|
“ASIO clock sample rate (xxkHz) doesn't match driver's sample rate (xxkHz)”
...
Panel |
---|
|
- Set your DAW sampling rate as the RAVENNA network one, or set the RAVENNA network sample rate as the DAW one.
- In ANEMAN, you can create a Sample Rate zone, so all devices in this zone will follow the sampling rate.
- If you have several devices on the same RAVENNA network, make sure the PTP Master is set to the same sampling rate as the ASIO driver.
You may alternatively set the device ASIO Clock (Setup > System) to Off on the Master PTP device and On on the device connected to ASIO.
|
“ASIO Clock error : latency of the master Horus/Hapi and ASIO drive must be set accordingly"
The latency of the ASIO driver and the Horus/Hapi do not match.
Image Added
Panel |
---|
|
Depending on your requirements :
- Change the Latency setting in the ASIO Panel : 64 or 48(AES67)
- Or change the Latency setting in Horus/Hapi Setup > System page.
|
“no ASIO Host connected”
...