Table of Contents |
---|
...
- Enter the authorization key
Open the MT Security Settings panel and import your key, depending on your licensing method, dongle or cloud licensing.
After importing your key, you should see the ASIO ST2022-7 option active in the authorizations list. - Configure the IP addresses on the device
In this example we will use an Anubis SPS device.
Long press the Merging logo button and access the settings.
Browse to the General > Network section.
Make sure the ST2022-7 mode option is active.
Configure the IP addresses on both Interface 1 and 2.
Note : The IP addresses range should be in different IP range to avoid IP conflicts.
Please see this page if you need help and details on IP addresses conflicts
Once finished, press on Apply & Reboot. - Configure the IP addresses on the computer
In this example, we will assume you have 2 Network adapters on your computer and one Anubis SPS device, but the same procedure applies if you run with 2 devices.
Go in Windows Control Panel > Network and Sharing Center, then click on Change Adapter settings (left)
Right click on the adapter that you have to configure and select Properties.
Select the Internet Protocol Version 4 (TCP/IP), then click on the Properties button.
Set it to "Use the following IP addresses", then enter the IP address.
It must be in the same range as the Interface 1 set on the Anubis SPS device, for example : adapter IP is 172.168.0.10 and Anubis Interface 1 is 172.168.0.20
The Subnet mask is mandatory; Windows can set it automatically, simply click in the Subnet mask field.
You may need to also change the attached network device(s) IP address, consult their documentation for details.
The IP address 127.0.0.0 should NEVER be used.
Repeat the same operation on the second network adapter, this time in the same IP range as the Interface 2 set on the Anubis SPS device, for example adapter IP is 169.254.65.10 and Anubis Interface 2 is 169.254.65.20
Once finished, please reboot your computer. - Configure the Merging RAVENNA ASIO / Merging Audio Device driver
Open the Merging RAVENNA ASIO panel / Merging Audio Device panel
In the RAVENNA / AES67 Settings section, simply select the network adapter that was configured for Interface 1 as Primary adapter.
Then select the network adapter that was configured for Interface 2 as Secondary adapter.
Press Apply
(The other Merging Audio Device settings are described on this page) - Make the audio connections in the Advanced pages
Open MT Discovery
Right click on one of the Anubis device and select Open Advanced
In the General Settings page, ST2022-7 mode should be active, and both Interface should be Up.
Go in the Session Sources page and create a new Source.
Set the Output Interface(s) to Interface 1&2 (ST2022-7)
The other parameters should be configured the usual way (channel count, inputs,....)
Open now the Advanced pages on the ASIO device.
In the General Settings page, ST2022-7 mode should be active, and both Interface should be Up as well.
Go in the Session Sinks page and create a new Sink.
In the Source drop down menu, select the required Source (the system will detect that source is ST2022-7)
The Anubis source is now connected to the ASIO in ST2022-7. The connection status for both interface is displayed on the left hand pane.
Repeat the operation on the ASIO Session Sources - Anubis Session Sinks to connect audio from ASIO to Anubis.
Tip | ||
---|---|---|
| ||
Notes :
|