Note | ||
---|---|---|
| ||
Important: |
Table of Contents
Installation
...
- PMX140-36: Fixed. Stereo Dual Pan
- PMX140-39: TC Generator plugin: mute on stop by default
- Atmos ADM Import - Fixed import of FFOA at 00:00:00:00
- Atmos ADM Import - Fixed import of NOT_INDICATED render wrap mode
- Several Atmos maintenance
- Mixer Strip panner may display wrong front/rear values (display issue only)
Fixed Bugs in Ovation 10 RC1
...
- Windows 10 (64bit) is supported by Pyramix 14 MassCore RAVENNA Ovation 10 MassCore RAVENNA and Native
- Windows 11 (64bit) is supported by Pyramix 14 Ovation 10 Native
- Ovation 10 system recommendations. Details here: http://www.merging.com/pages/pcconfig
- For ultimate performance we recommend that under ANEMAN you only connect the necessary I/O connections, as every extra RAVENNA connection will use some bandwidth (Core or Network)
- The Network must be Layer 3 compliant and must be a Gigabit network
- Merging has certified new Network Switches for use with Horus/Hapi – Ravenna users will find all details along with the configuration guide here:
https://confluence.merging.com/display/PUBLICDOC/Network+Switches+for+RAVENNA+-+AES67
http://www.merging.com/products/horus/downloads - RAVENNA users should avoid connecting multiple Horus or Hapi units to any a router/Network not certified by Merging. Refer to the Merging RAVENNA Network Guide for details on the certified RAVENNA switches and their configuration. http://www.merging.com/products/horus/downloads
- Only RAVENNA devices can be connected to the Merging PCIe Ethernet Controller Card NET-MSC-GBEX1. Avoid connecting non-RAVENNA devices to this network, such as Tango/Isis/Euphonix controllers or other network devices.
- Don’t connect a 100MB Ethernet device if the switch is not multicast; otherwise, the flow control will reduce the bandwidth drastically.
- RAVENNA I/O Connections:
In order to create RAVENNA I/O connections please refer to the ANEMAN User Manual (installed along with Pyramix). ANEMAN Quick Connection Guide here below.
https://confluence.merging.com/display/PUBLICDOC/ANEMAN+-+Quick+Connection+Guide
Refer to the ANEMAN User Manual for more details.
Recalling RAVENNA connections for a complete setup.
Despite not yet having a complete recall of IO Connections it is possible on certain setups to recall the Presets store in the device (Horus, Hapi, Anubis) that holds one end of the RAVENNA connections and at the same time recall the ANEMAN save connections that holds the other connections end.
Warning: It is strongly advised that before recalling connection that users clear the existing connections. - Firewall:
Firewalls can block communication between the computer and the Ravenna devices.
The Merging installers automatically opens the required communication ports in the Windows Firewall.
If you don’t use the Windows firewall or if you encounter connection issues, we recommend to disable the Network Firewall.
Windows Firewall Procedure:
Go in Windows Control Panel > Windows Firewall.
Click on “Turn Windows Firewall on or off”
Go to the Public Network section and select “Turn Off Windows Firewall”
For other firewalls, please consult the manufacturer documentation. - Windows UAC:
User should disabled the Windows User Account Control
Procedure:
Go to the Windows Control Panel\All Control Panel Items\User Accounts
Open the Change User Account Setting
And set it to “Never Notify” - Antivirus:
Some Antivirus such as Avast or Sophos have been known to block the Horus discovery and RAVENNA I/O Connection. Merging also recommends that any Antivirus software is properly configured to not interfere with the DAW. See this page for further details:
https://confluence.merging.com/display/PUBLICDOC/Antivirus+and+Merging+Technologies+Softwares
...