The RAVENNA device and the host sampling rate are not matching - Set the required sampling rate in the device or the host.
- You may also use the "Easy Force all connected devices" checkbox, to force any RAVENNA device displayed to follow the host sampling rate.
- If you share a RAVENNA device between several hosts, make sure that all hosts are set to the same sampling rate, and that the Easy-force feature is turned off on all hosts.
|
Problem
Cannot connect some RAVENNA modules or IO numbering never gets cleared up.
Solution
Panel |
---|
|
Force a clear of the RAVENNA Easy Connect IO - Open the Easy Connect
- Perform a CTRL + Clear All Connections
Warning: When selecting CTRL along with the Clear All Connextion this will clear all of the RAVENNA IO on the same local RAVENNA network, it will not affect the grayed out RAVENNA devices (as of v10.0) - If you still have ghost connections, try to Quit Easy Connect from by right clicking on its icon in Windows notification area, and re-open it.
- This will re-discover the RAVENNA devices and republish the IO listing
|