In the Anubis Settings > General, disable the PTP Master option.
Note Notes:
This step is required because only the Master PTP device can be synced on an external clock.
The PTP status may remain on Master, this is not a problem at this step.In the peered device, set it to sync on the external clock.
In our example, a peered Hapi MKII is set to sync on an incoming Wordclock
Go in the IO & Sync page, and select the WCK.Notes:
The peered device will change to PTP Master, and the Anubis will change to PTP slave, automatically.
If you want the peered device to automatically follow the external clock sampling rate, activate its Auto sampling rate option.
Depending on the clock type, the Auto sampling rate should not be enabled, e.g. if receiving a 48Khz Wordclock and willing to run at 96 Khz.In this kind of setup, the Anubis sampling rate will not follow automatically.
Manually
Aneman SR Zone
Auto Sampling rate
See ANUBIS-1425
This is not working, because it’s not the way peering has been designed !!!!
When peering, the Anubis is expected to be the SR master, and it sends its SR to the satellite device (Hapi in this case).
The Anubis is sending its SR to the satellite device 1 time, if the satellite does not follow or change its SR afterwards, it will not send it back.
This is to avoid SR going back and forth on the satellite if 2 Anubis running at different sampling rates are peering the same satellite device.
...