Prerequisites

  • Pyramix v15.0 (or above) installed and authorized

  • MassCore engine (RTX64 4.5.1 or above) installed and authorized.

  • 2x MassCore NIC cards of the same generation installed and running in your computer; either 2x NET-MSC-GBEX1 or 2x
    Using different MassCore NIC card models is not allowed.

  • Compatible Merging RAVENNA/AES67 device(s) configured in ST2022-7 mode (e.g. Anubis SPS, Hapi MKII), connected to the MassCore NICs

...

Procedure

  1. Make sure your Merging RAVENNA/AES67 device(s) is running in Multi Interface / ST2022-7 Mode (see Anubis SPS Settings or Hapi MkII/MKIII Setup - Network).

  2. Configure the device(s) IP addresses (the 2 networks should be in different IP ranges) on the device.
    Note: a device reboot is required to activate the ST2022-7 mode and after any change to the IP addresses.
    Refer to the device User Manuel for further details.

  3. Start the VS3 Control Panel in Administrator mode.
    The MassCore Primary Network adapter should be already filled in.

  4. Add a the Secondary Network adapter NIC and press Apply.

  5. A secondary Ravenna icon will show up.
    If both networks cable are plugged, both icons should show active.
    If both networks are not connected, MassCore will not start.

    VS3CP-2022-7.png
  6. Configure the device(s) MassCore Primary and Secondary Network Adapters IP addresses (the 2 networks should be in different IP ranges) on the computer.
    Go in Windows Control Panel - Network and Sharing Center - Change adapter Settings.
    Set an IP address on the Merging Technologies Primary Ethernet Controller and Merging Technologies Secondary Ethernet Controller.

    MSC2022-7-WinNetConfig.png
  7. Press OK to close the VS3 Control Panel.

  8. Start Pyramix / Ovation MassCore