In addition, MassCore users have to verify - MassCore RTX64 must be installed.
Make sure in Windows Control Panel > Programs & Features that Interval Zero RTX64 is installed. - MassCore RTX64 must be authorized.
Go in Windows Control Panel > RTX64, and check that it is licensed, under RTX64 Components Components. - MassCore RTX64 must be running.
Go in Windows Control Panel > RTX64 and check that the Subsystem is started. - Merging Technologies MassCore NIC must be running.
Go in Windows Control Panel > Administrative Tools > Services, and make sure that this service is running. You can Restart the service to be sure it runs properly. - The RAVENNA device must be plugged on the Merging MassCore NIC (NET-MSC-GBEX1)
- The Merging MassCore NIC must be working.
Go in Windows Control Panel > Device Manager > Network adapters and make sure Merging Technologies PCIe 82574L Ethernet Controller has a valid driver, without any ! or ? sign icon. Refer to this page if you need to reinstall the driver.
|