Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Do not have the Background Recorders that you want to remove selected in the Transport.
Please monitor you memory usage and it might be a good thing to reduce the Pre-Buffering and the track record count.
 

Background Recorders DSD

If the Mixer is not a DSD compatible Mixer (square mixer), the record fails, but no message displayed. We recommend users to create a DSD project prior to enabling and starting to work with Background Recorders in DSD.

Safety Record issue with the take logger.

Pressed commands erroneously will be applied when the transport is stopped. Meaning that if you press Abort & Delete while in safety record, nothing will happen. But, when you come out of safety record and stop, it will apply the command and delete the take. To handle with care.

Take logger buttons do not show up in dialog, Rating icons not visible

...

Add an effect (any effect will do, but you may prefer to pick one that doesn’t modify the sound: phase oscillo, surround monitor…) on the bus that Final Check doesn’t monitor.
Then disable - enable Final Check Metering. 

Multiple projects opened simultaneously

We do not recommend users to have more than 8 project opened at the same time (due to GDI object limitation).