Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. On each Horus, select Video in the I/O & Sync Page.
    On the PTP Master PTP, the Horus will be synchronized on Video, the PTP slave will show Video sync red :



  2. Open the advanced pages of the slave device, and go in the PTP tab.

  3. Tick the "Manual" box and set "Priority 1" to 130 (Default value 127).
    The other PTP Parameters should not be modified.
    Image Removed

...


  1. Image Added

    If the Master PTP device fails, the Slave device will turn to Master.
    This change does require several seconds, and during that time, the audio might be degraded.
    Image Added

    When the previous PTP Master comes back, it will turn to Master, which may also require several seconds.

 

Tip
titlePTP Priority values

High values have low priority, and low values have high priority; 1 is the highest priority and 255 the lowest.
By default, all Merging devices are set with a priority value of 127, and an internal algorithm is used to determine which device is elected as master when several devices have the same PTP priority value.

...