Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • MassCore Pyramix or Ovation installed.
  • Merging Audio device driver v2.0 (or above) installed.
  • MassCore Network Card (NET-MSC-GBEX1)
  • Merging RAVENNA/AES67 device connected to the MassCore card.

Procedure

  1. Start the Merging Audio Device panel.
  2. Select the MASSCORE mode tab and confirm you want to switch the mode.

    Note : The panel will indicate that the Bridge is not initialized and MassCore not running, that is normal.

  3. Click on the Advanced Settings button at the bottom of the UI.


  4. Now the number of channels needs to be set.
    Click on the value next to Inputs or Outputs (in this mode, the number of channels for inputs and outputs is the same.)
    Select the Change... value


  5. This will automatically open the VS3 Control Panel.
    Please make sure that Pyramix or Ovation Platform is set to MassCore.

  6. In the Audio Bridge section at the bottom of the panel, activate the MT ASIO bridge Host.
    Set the required Number of Channels (I/O)
    Press OK to confirm and close the panel.


    Note : the number of channels values will be updated automatically in the MAD panel.

  7. Start your MassCore Pyramix / Ovation.
    The MT ASIO bridge inputs 
    ASIO DAWinputs and outputs are now available in your mixer.
    Note : Currently the MT ASIO Bridge is not compatible with DSD sampling rates (please use DXD projects with Hepta SRC)

  8. Start your third party ASIO Application(s) and set it to use the Merging Audio Device driver.


BRIDGE CHANNELS MSC