Multiple RAVENNA devices - External clock

Multiple RAVENNA devices - External clock

When several RAVENNA devices are present on the same network, one is elected as PTP Master, and the other ones as PTP Slave.
Only the PTP Master is able to lock to an external reference (i.e. Wordclock, Video reference,...)
If the PTP Master device fails, one of the Slave device will be elected to Master, but by default will be on its internal clock.


Setup example :

- Horus 1 master with sync on Video Ref.
- Horus 2 slave, needs to fallback as master with sync on Video Ref.

Prerequisite

Your Merging RAVENNA device must be running firmware 3.9.0b34718 or above.

 

On each Horus, select Video in the I/O & Sync Page.
On the PTP Master, the Horus will be synchronized on Video, the PTP slave will show Video sync red :



If the Master PTP device fails, the Slave device will turn to Master.
This change does require several seconds, and during that time, the audio might be degraded.


When the previous PTP Master comes back, it will turn to Master, which will also require several seconds for the PTP clock to synchronize, and during that time the audio might be degraded.  You may therefore choose to not restart the device.


If you have a more complex setup, additional settings should be configured, feel free to contact support@merging.com for further help.



Related content

Network Switches for RAVENNA - AES67
Network Switches for RAVENNA - AES67
Read with this
Multiple RAVENNA devices - PTP Priorities considerations.
Multiple RAVENNA devices - PTP Priorities considerations.
More like this
Merging RAVENNA Advanced Pages User Guide.
Merging RAVENNA Advanced Pages User Guide.
Read with this
MERGING+CLOCK Quick Start
MERGING+CLOCK Quick Start
More like this
AES67 - RAVENNA devices interoperability
AES67 - RAVENNA devices interoperability
Read with this
Ovation redundancy - MultiSequencer Synchronization
Ovation redundancy - MultiSequencer Synchronization
More like this